JAMA & ARCHIVES
Arch Fam Med
SEARCH
GO TO ADVANCED SEARCH
HOME  PAST ISSUES  TOPIC COLLECTIONS  CME  PHYSICIAN JOBS  CONTACT US  HELP
Institution: STANFORD Univ Med Center  | My Account | E-mail Alerts | Access Rights | Sign In
  Vol. 9 No. 6, June 2000 TABLE OF CONTENTS
  Archives
  •  Online Features
  Original Contribution
 This Article
 •Full text
 •PDF
 •Send to a friend
 • Save in My Folder
 •Save to citation manager
 •Permissions
 Citing Articles
 •Citation map
 •Citing articles on HighWire
 •Citing articles on Web of Science (44)
 •Contact me when this article is cited
 Related Content
 •Related article
 •Similar articles in this journal
 Topic Collections
 •Hypertension
 •Alert me on articles by topic

How Often Do Office Blood Pressure Measurements Fail to Identify True Hypertension?

An Exploration of White-Coat Normotension

Christopher Selenta, BA; Brenda E. Hogan, MA; Wolfgang Linden, PhD

Arch Fam Med. 2000;9:533-540.

Background  The often-observed differences between ambulatory (ABP) and office blood pressure (OBP) measurements have brought attention to the problem of misdiagnoses. Although there has been much focus on white-coat hypertension (elevated OBP with normal ABP means), few studies have examined "white-coat normotension" (WCN; normal OBP with elevated ABP means).

Objectives  To describe patients with WCN in terms of prevalence and quantitative differences between ABP and OBP; to identify psychological and demographic features that discriminate them from true normotensive patients; and to offer possible corrections for diagnostic limitations of OBP measurements in clinical practice.

Design and Methods  Five OBP measurements and 10- to 12-hour daytime ABP monitoring in 319 presumed healthy participants.

Results  Prevalence rates of WCN were 23% for systolic BP and 24% for diastolic BP. Participants with WCN were more often male, past smokers, and older and consumed more alcohol. Increasing the number of office readings and discarding the first office reading did not improve the accuracy of OBP measurements. Participants with BP of 10 mm Hg above or below the 140/90 office reading cutoff showed the lowest accuracy, with more than 50% of normotensive diagnoses being incorrect.

Conclusions  Office measures of BP lack sensitivity, missing a sizable portion of individuals who have hypertensive mean ABP measurements. Subjects with WCN differ from true normotensive subjects on several demographic and lifestyle variables. Only those office readings averaging 20 points above or below the 140/90 cutoff represent safe diagnostic information.


From the Department of Psychology, University of British Columbia, Vancouver (Ms Hogan and Dr Linden). Mr Selenta is now affiliated with the Department of Psychology, University of Akron, Akron, Ohio.


RELATED ARTICLE

The Archives of Family Medicine Continuing Medical Education Program
Arch Fam Med. 2000;9(6):551-552.
FULL TEXT  


THIS ARTICLE HAS BEEN CITED BY OTHER ARTICLES

Disparate Estimates of Hypertension Control From Ambulatory and Clinic Blood Pressure Measurements in Hypertensive Kidney Disease
Pogue et al.
Hypertension 2009;53:20-27.
ABSTRACT | FULL TEXT  

Prevalence and Clinical Significance of Isolated Ambulatory Hypertension in Young Subjects Screened for Stage 1 Hypertension
Palatini et al.
Hypertension 2004;44:170-174.
ABSTRACT | FULL TEXT  

Cardiovascular Prognosis of "Masked Hypertension" Detected by Blood Pressure Self-measurement in Elderly Treated Hypertensive Patients
Bobrie et al.
JAMA 2004;291:1342-1349.
ABSTRACT | FULL TEXT  

Masked Hypertension
Pickering et al.
Hypertension 2002;40:795-796.
FULL TEXT  

The Urgent Need to Improve Hypertension Care
Trilling and Froom
Arch Fam Med 2000;9:794-801.
ABSTRACT | FULL TEXT  




HOME | CURRENT ISSUE | PAST ISSUES | TOPIC COLLECTIONS | CME | PHYSICIAN JOBS | HELP
CONDITIONS OF USE | PRIVACY POLICY | CONTACT US | SITE MAP
 
© 2000 American Medical Association. All Rights Reserved.