<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE Publisher PUBLIC "-//MetaPress//DTD MetaPress 2.0//EN" "http://public.metapress.com/dtd/MPRESS/MetaPressv2.dtd">
<Publisher>
	<PublisherInfo>
		<PublisherName>Baywood Publishing Company</PublisherName>
	</PublisherInfo>
	<Journal>
		<JournalInfo JournalType="Journals">
			<JournalPrintISSN>0047-2433</JournalPrintISSN>
			<JournalElectronicISSN>1541-3802</JournalElectronicISSN>
			<JournalTitle>Journal of Environmental Systems</JournalTitle>
			<JournalCode>BWES</JournalCode>
			<JournalID>300323</JournalID>
			<JournalURL>http://baywood.metapress.com/link.asp?target=journal&amp;id=300323</JournalURL>
		</JournalInfo>
		<Volume>
			<VolumeInfo>
				<VolumeNumber>28</VolumeNumber>
			</VolumeInfo>
			<Issue>
				<IssueInfo IssueType="Regular">
					<IssueNumberBegin>4</IssueNumberBegin>
					<IssueNumberEnd>4</IssueNumberEnd>
					<IssueSupplement>0</IssueSupplement>
					<IssuePartStart>0</IssuePartStart>
					<IssuePartEnd>0</IssuePartEnd>
					<IssueSequence>000028000420010401</IssueSequence>
					<IssuePublicationDate>
						<CoverDate Year="2001" Month="4" Day="1"/>
						<CoverDisplay>Number 4/2000-2001</CoverDisplay>
					</IssuePublicationDate>
					<IssueID>6CC6LH82T58A</IssueID>
					<IssueURL>http://baywood.metapress.com/link.asp?target=issue&amp;id=6CC6LH82T58A</IssueURL>
				</IssueInfo>
				<Article ArticleType="Original">
					<ArticleInfo Free="No" ESM="No">
						<ArticleDOI>10.2190/03BE-14AX-D8K8-E56T</ArticleDOI>
						<ArticlePII>03BE14AXD8K8E56T</ArticlePII>
						<ArticleSequenceNumber>271</ArticleSequenceNumber>
						<ArticleTitle Language="En">ON MANAGING INDOOR AIR QUALITY IN HONG KONG</ArticleTitle>
						<ArticleFirstPage>271</ArticleFirstPage>
						<ArticleLastPage>277</ArticleLastPage>
						<ArticleHistory>
							<RegistrationDate>20021002</RegistrationDate>
							<ReceivedDate>20021002</ReceivedDate>
							<Accepted>20021002</Accepted>
							<OnlineDate>20021002</OnlineDate>
						</ArticleHistory>
						<FullTextFileName>03BE14AXD8K8E56T.pdf</FullTextFileName>
						<FullTextURL>http://baywood.metapress.com/link.asp?target=contribution&amp;id=03BE14AXD8K8E56T</FullTextURL>
						<Composite>4</Composite>
					</ArticleInfo>
					<ArticleHeader>
						<AuthorGroup>
							<Author AffiliationID="A1">
								<GivenName>W. K.</GivenName>
								<Initials/>
								<FamilyName>CHOW</FamilyName>
								<Degrees/>
								<Roles/>
							</Author>
							<Affiliation AFFID="A1">
								<OrgDivision/>
								<OrgName>The Hong Kong Polytechnic University</OrgName>
								<OrgAddress/>
							</Affiliation>
						</AuthorGroup>
						<Abstract Language="En">The local government of Hong Kong is going to implement new codes for controlling indoor air quality with the aim to provide a better environment. Different views were collected from the public on what should be done to give a good built environment. A wide area of application was proposed for the building management team to follow. However, the part on spaces with mechanical ventilation and air-conditioning (MVAC) system is not adequate. In this article, key aspects of indoor air quality for spaces with MVAC systems are discussed. Items that should be included in the new code are also outlined.</Abstract>
						<biblist>
							<bib-other>
								<bibtext seqNum="1">Addendum to Standard 62-1989, New Ventilation Rates Proposal, ASHRAE Journal, pp. 10-11, May 1999.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="2">H. Hanzawa, A. K. Melikov, and P. O. Fanger, Airflow Characteristics in the Occupied Zone of Ventilated Spaces, ASHRAE Transactions, 93(Part 1), pp. 524-539, 1987.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="3">Final Report: Consultancy Study for Indoor Air Pollution in Offices and Public Places in Hong Kong, Environmental Protection Department, Hong Kong Special Administrative Region, October 1999.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="4">Occupational Health Pictorial Guide--Occupational Health Office Environment, Labour Department, Hong Kong Special Administrative Region, 1999.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="5">W. K. Chow and W. Y. Fung, Indoor Thermal Environment Survey in Air-Conditioned Shopping Malls in Hong Kong, Indoor Environment, 4:2, pp. 102-112, 1995.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="6">P. C. H. Yu and W. K. Chow, Sizing of Air-Conditioning Plant for Commercial Buildings in Hong Kong, Applied Energy, 66:2, pp. 91-103, 2000.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="7">Code of Practice for the Management of Indoor Air Quality (draft), Environmental Protection Department, Hong Kong Special Administrative Region, November 1999.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="8">Laws of the Hong Kong Special Administrative Region including the Buildings Ordinance (Cap 123), updated in September 1999; and Building (Ventilation Systems) Regulations, Hong Kong Special Administrative Region, January 1999.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="9">Apple Daily, February 9, 2001.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="10">Practice Notes for Authorized Persons and Registered Structural Engineers: PNAPZ19 Lighting and Ventilation for Bathrooms in Domestic Buildings, Buildings Department, Hong Kong Special Administrative Region, December 1997.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="11">W. K. Chow, L. T. Wong, and W. Y. Fung, Field Measurement of the Air Flow Characteristics of Big Mechanically Ventilated Spaces, Building and Environment, 31:6, pp. 541-550, 1996.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="12">W. K. Chow, A Comment on Studying the Ventilation Requirements for Buildings in Hong Kong Special Administrative Region, International Journal on Architectural Science, 1:1, pp. 1-13, 2000.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="13">A. K. Melikov, Quantifying Draught Risk, Bruel and Kjaer Technical Review No. 2, (1987).</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="14">M. E. Fountain and E. A. Arens, Air Movement and Thermal Comfort, ASHRAE Journal, 31:8, pp. 26-30, 1993.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="15">ASHRAE Standard 62-1989, Ventilation for Acceptable Indoor Air Quality, American Society for Heat, Refrigerating and Air-Conditioning Engineers, Atlanta, Georgia, U.S.A., 1989.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="16">W. K. Chow and W. Y. Fung, Investigation of the Subjective Response to Elevated Air Velocities: Climate Chamber Experiments in Hong Kong, Energy and Buildings, 20:3, pp. 187-192, 1994.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="17">R. J. de Dear and M. E. Fountain, Thermal Comfort in Air-Conditioned Office Buildings in the Topics, AIRH Journal, 48:9, pp. 14-30, 1994.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="18">Consultancy Agreement Brief, Review of Lighting and Ventilation Requirements in Buildings, Buildings Department, Hong Kong Special Administrative Region, 1999.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="19">W. K. Chow and W. Y. Fung, Studies on the &quot;Ventilation Effectiveness&quot; and Modification of the Ventilation System in the Waiting Hall of a Railway Station, Indoor + Built Environment, 5:5, pp. 280-290, 1996.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="20">B. W. Olesen, Standards for Design and Evaluation of Indoor Thermal Environment, ASHRAE Journal, 35:8, pp. 20-25, 1993.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="21">W. K. Chow and W. Y. Fung, Survey of the Design Considerations for Ventilating and Air-Conditioning Systems in Hong Kong, ASHRAE Transactions: Research, 102(Part 2), pp. 210-219, 1996.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="22">D. Etheridge and M. Sandberg, Building Ventilation: Theory and Measurement, John Wiley &amp; Sons, Chichester, 1996.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="23">Y. N. Au Yeung, W. K. Chow, and V. Y. K. Lam, Sick Building Syndrome--A Case Study, Building and Environment, 26:4, pp. 319-330, 1991.</bibtext>
							</bib-other>
						</biblist>
					</ArticleHeader>
				</Article>
			</Issue>
		</Volume>
	</Journal>
</Publisher>