<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE Publisher PUBLIC "-//MetaPress//DTD MetaPress 2.0//EN" "http://public.metapress.com/dtd/MPRESS/MetaPressv2.dtd">
<Publisher>
	<PublisherInfo>
		<PublisherName>Baywood Publishing Company</PublisherName>
	</PublisherInfo>
	<Journal>
		<JournalInfo JournalType="Journals">
			<JournalPrintISSN>0047-2433</JournalPrintISSN>
			<JournalElectronicISSN>1541-3802</JournalElectronicISSN>
			<JournalTitle>Journal of Environmental Systems</JournalTitle>
			<JournalCode>BWES</JournalCode>
			<JournalID>300323</JournalID>
			<JournalURL>http://baywood.metapress.com/link.asp?target=journal&amp;id=300323</JournalURL>
		</JournalInfo>
		<Volume>
			<VolumeInfo>
				<VolumeNumber>5</VolumeNumber>
			</VolumeInfo>
			<Issue>
				<IssueInfo IssueType="Regular">
					<IssueNumberBegin>4</IssueNumberBegin>
					<IssueNumberEnd>4</IssueNumberEnd>
					<IssueSupplement>0</IssueSupplement>
					<IssuePartStart>0</IssuePartStart>
					<IssuePartEnd>0</IssuePartEnd>
					<IssueSequence>000005000419750101</IssueSequence>
					<IssuePublicationDate>
						<CoverDate Year="1975" Month="1" Day="1"/>
						<CoverDisplay>Number 4 / 1975</CoverDisplay>
					</IssuePublicationDate>
					<IssueID>R15HCWK6W64V</IssueID>
					<IssueURL>http://baywood.metapress.com/link.asp?target=issue&amp;id=R15HCWK6W64V</IssueURL>
				</IssueInfo>
				<Article ArticleType="Original">
					<ArticleInfo Free="No" ESM="No">
						<ArticleDOI>10.2190/CUFR-JK97-5L3U-P3CB</ArticleDOI>
						<ArticlePII>CUFRJK975L3UP3CB</ArticlePII>
						<ArticleSequenceNumber>3</ArticleSequenceNumber>
						<ArticleTitle Language="En">An Air Sampling system to Measure Power Plant Effluents Using a Lightweight Aircraft</ArticleTitle>
						<ArticleFirstPage>271</ArticleFirstPage>
						<ArticleLastPage>289</ArticleLastPage>
						<ArticleHistory>
							<RegistrationDate>20020509</RegistrationDate>
							<ReceivedDate>20020509</ReceivedDate>
							<Accepted>20020509</Accepted>
							<OnlineDate>20020509</OnlineDate>
						</ArticleHistory>
						<FullTextFileName>CUFRJK975L3UP3CB.pdf</FullTextFileName>
						<FullTextURL>http://baywood.metapress.com/link.asp?target=contribution&amp;id=CUFRJK975L3UP3CB</FullTextURL>
						<Composite>4</Composite>
					</ArticleInfo>
					<ArticleHeader>
						<AuthorGroup>
							<Author AffiliationID="A1">
								<GivenName>Anthony</GivenName>
								<Initials>J.</Initials>
								<FamilyName>Romano</FamilyName>
								<Degrees/>
								<Roles/>
							</Author>
							<Author AffiliationID="A1">
								<GivenName>James</GivenName>
								<Initials>H.</Initials>
								<FamilyName>Klein</FamilyName>
								<Degrees/>
								<Roles/>
							</Author>
							<Author AffiliationID="A1">
								<GivenName>Leonard</GivenName>
								<Initials/>
								<FamilyName>Newman</FamilyName>
								<Degrees/>
								<Roles/>
							</Author>
							<Affiliation AFFID="A1">
								<OrgDivision/>
								<OrgName>Brookhaven National Laboratory, Upton, New York</OrgName>
								<OrgAddress/>
							</Affiliation>
						</AuthorGroup>
						<Abstract Language="En">&lt;p&gt;An air sampling system to measure power plant effluents from a fixed-wing, light aircraft has been developed and evaluated both in the laboratory and in the field. The sampling system is easily adaptable to a Cessna 206 and provides the capability to measure oxides of sulfur, oxides of nitrogen, particulates and SF&lt;sub&gt;6&lt;/sub&gt; tracer gas.&lt;/p&gt;&lt;p&gt;Evaluation of the apparatus has indicated that real-time measurements of the conversion of NO to NO&lt;sub&gt;2&lt;/sub&gt; in the plume at distances up to twenty-five miles are feasible. The oxides of sulfur are measured by a technique employing KOH impregnated filter papers which has been proven to have very high reliability and precision.&lt;/p&gt;&lt;p&gt;The applicability, precision, and reliability of the entire sampling system are being evaluated in field operations in St. Louis, Missouri. Results of these tests will be the subject of upcoming papers.&lt;/p&gt;</Abstract>
						<biblist>
							<bib-other>
								<bibtext seqNum="1">&quot;The 1970 National Power Survey,&quot; Federal Power Commission, pp. I-11-2, December 1971.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="2">Altshuller, &quot;Atmospheric Sulfur Dioxide and Sulfate—Distribution of Concentration at Urban and Non-urban Sites in United States,&quot; &lt;i&gt;Environmental Science and Technology, 7&lt;/i&gt;, pp. 709-712, 1973.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="3">Johnson and Atkins, &quot;An Airborne System for the Sampling and Analysis of Sulphur Dioxide and Atmospheric Aerosols,&quot; &lt;i&gt;Atmospheric Environment, 9&lt;/i&gt;, p. 825, 1975.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="4">Davis, Smith and Klauber, &quot;Trace Gas Analysis of Power Plant Plumes via Aircraft Measurements: O&lt;sub&gt;3&lt;/sub&gt;, NO&lt;sub&gt;x&lt;/sub&gt; and SO&lt;sub&gt;2&lt;/sub&gt; Chemistry,&quot; &lt;i&gt;Science, 186&lt;/i&gt;, p. 733, 1974.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="5">Manowitz, Newman and Tucker, &quot;The Atmospheric Diagnostics Program at Brookhaven National Laboratory: Fourth Status Report,&quot; BNL 50361, June 1972.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="6">Newman, Forrest and Manowitz, &quot;The Application of An Isotopic Ratio Technique to a Study of the Atmospheric Oxidation of Sulfur Dioxide in the Plume from an Oil Fired Power Plant,&quot; &lt;i&gt;Atmospheric Environment, 9&lt;/i&gt;, p. 959, 1975.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="7">Newman, Forrest and Manowitz, &quot;The Application of An Isotopic Ratio Technique to a Study of the Atmospheric Oxidation of Sulfur Dioxide in the Plume from a Coal Fired Power Plant,&quot; &lt;i&gt;Atmospheric Environment, 9&lt;/i&gt;, p. 969, 1975.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="8">Forrest and Newman, &quot;Sampling and Analysis of Atmospheric Sulfur Compounds for Isotope Ratio Studies,&quot; &lt;i&gt;Atmospheric Environment, 7&lt;/i&gt;, p. 561, 1973.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="9">Rittenberg, Keston, Rosebury and Schoenheimer, &lt;i&gt;J. Biol. Chem., 127&lt;/i&gt;, p. 291, 1939.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="10">Dietz and Cote, &quot;Tracing Atmospheric Pollutants by Gas Chromatographic Determination of Sulfur Hexfluoride,&quot; &lt;i&gt;Environmental Science and Technology, 7&lt;/i&gt;, p. 338, 1973.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="11">Manowitz, Smith, Steinberg and Tucker, &quot;Status Report on BNL Atmospheric Diagnostics Program,&quot; Informal Report BNL 11465, June 1967.</bibtext>
							</bib-other>
							<bib-other>
								<bibtext seqNum="12">Stevens, Clark, Baumgardner and Hodgeson, &quot;Instrumentation for the Measurement of Nitrogen Dioxide,&quot; ASTM Special Technical Publication 555.</bibtext>
							</bib-other>
						</biblist>
					</ArticleHeader>
				</Article>
			</Issue>
		</Volume>
	</Journal>
</Publisher>